generated

TripleCLIPLoaderGGUF

TripleCLIPLoaderGGUF loads three CLIP/text-encoder models stored in the GGUF quantized format and combines them into a single CLIP object.

Triple CLIP Loader GGUF

CLIP
clip_name1
COMBO
clip_name2
COMBO
clip_name3
COMBO
GGUF

Description

TripleCLIPLoaderGGUF loads three CLIP/text-encoder models stored in the GGUF quantized format and combines them into a single CLIP object. It is the three-encoder counterpart to the single and dual GGUF CLIP loaders, and exists for model architectures that expect more than one text encoder working together (for example, pipelines that pair a main text encoder with additional encoders for conditioning, refinement, or detail).

Because the loaders in ComfyUI-GGUF read GGUF files instead of the standard .safetensors weights, this node lets you run multi-encoder models with heavily quantized text encoders, which substantially reduces VRAM and RAM usage compared with full-precision equivalents. The node does not download anything: the model files must already be present in the ComfyUI model directory that the GGUF loaders search (typically ComfyUI/models/clip, or ComfyUI/models/text_encoders depending on your installation).

Inputs

InputTypeDescription
clip_name1Model file selectionThe first GGUF CLIP/text-encoder file to load.
clip_name2Model file selectionThe second GGUF CLIP/text-encoder file to load.
clip_name3Model file selectionThe third GGUF CLIP/text-encoder file to load.

All three file selections must point to valid GGUF files. There is no type widget: the loader always assembles the three encoders as an SD3-style CLIP (CLIP-L, CLIP-G and T5), so it is meant for checkpoints that expect that trio. Files from a different architecture produce errors or unusable conditioning rather than a silently degraded result.

Outputs

OutputTypeDescription
CLIPCLIPThe combined text-encoder object, ready to be connected to CLIPTextEncode or any other node that accepts a CLIP input.

The output is a single merged CLIP, not three separate ones. Downstream nodes therefore see the three encoders as one conditioning source, which is exactly what multi-encoder architectures expect.

Usage Notes

  • No type to choose. The loader always builds the SD3-style triple (CLIP-L, CLIP-G, T5), so select three files from that trio; there is no dropdown that changes the architecture.
  • Keep all three encoders consistent. The files you select should belong to the same model family and be mutually compatible, since they are loaded as a set.
  • Quantization trades precision for memory. Lower-bit GGUF files use less memory and load faster, but very aggressive quantization can slightly change text-encoding behavior. If output quality looks off, try a higher-bit variant of the encoder files before changing other settings.
  • File placement. GGUF CLIP files are not auto-downloaded. Place them in the CLIP/text-encoder model directory that ComfyUI-GGUF reads, then refresh the node so the dropdowns pick them up.
  • Use the matching loader for your architecture. If your model only needs one or two text encoders, use the single or dual GGUF CLIP loader instead; loading extra encoders that the model does not expect will not work correctly.

Comments

Sign in with GitHub to join the discussion.

Loading comments…